Browse Categories

10 CFM Refrigerated Air Dryers

Price: $566.00
Item Number: F5/10
Manufacturer: WorldAir
Manufacturer Part No: F5/10
10 CFM Rated Capacity, 115/1/60 power requirement
 

Refrigerant System

 Highly Efficient Hermetic Compressor

 Thermally Protected

 Rubber Mounted

 Copper Tube and Aluminum Fin Condenser

 Constant Pressure Expansion Valve

 All Electrical Components Easily Accessible

 Universal CFC Free R-134A Refrigerant

Air System

 Enhanced Condensate Separator Includes 40 Micron Sintered Bronze Filtration

 Maximum Pressure Drop Less than 4 psi

Instrumentation

 Power On Light

 High Temperature Light

Cabinet

 Powder Coated Textured Paint Finish

 Heavy Duty Metal Construction

Electrical

 Lowest Power Consumption

 Several Available Voltages:

1.        115/1/60 or 100/1/50

2.        208-230/1/60 or 200-240/1/50

 2' Power Cord

Warranty

 2 Year Compressor Warranty

 5 Year Heat Exchanger Warranty

Optional Feature

 Electronic Timer Drain

Voltage Codes

Code #

Standard Volt/Phase/Hz

Export Volt/Phase/Hz

1

115/1/60

100/1/150

2

208-230/1/60

200-240/1/50

3

208-230/3/60

200-240/3/50

4

460/3/60

380/3/50

5

575/3/60

 

Standard Instrument Panels

 

A

B

C

D

E

F

On/Off Switch Light

 

X

X

X

X

X

Power On Light

X

 

 

 

 

 

High Temp Light

X

 

 

 

 

 

Refrigerant Suction Gauge

X

X

X

X

X

X

Air Inlet Temp Gauge

 

 

 

X

 

 

Discharge Pressure Gauge

 

 

 

 

 

X

Manual Drain Override

 

 

 

 

X

X

Drain Alarm Light

 

 

 

 

X

X

Air dryer rated flows are based upon design conditions of 100°F inlet, 100 psig and 100°F ambient. If these conditions vary, the rated flows will vary in accordance with the following general rules and tables.

As Inlet AIr Temperature increases, Flow Capacity will decrease:

Inlet AIr Temperature

90°F

95°F

100°F

110°F

120°F

Flow Capacity Multiplier

1.23

1.13

1.00

0.83

0.69

 

As Air Line Pressure increases, Flow Capacity will increase:

Air Line Pressure

60 psig

80 psig

100 psig

120 psig

150 psig

Flow Capacity Multiplier

.88

.95

1.00

1.04

1.08

 

As Ambient Air Temperature increases, Flow Capacity will decrease:

Ambient Air Temperature

80°F

90°F

100°F

110°F

Flow Capacity Multiplier

1.14

1.07

1.00

.92

 

As the Dew Point increases, Flow Capacity will increase: If design conditions (100ºF, 100 psig, 100ºF ambient) remain the same, but a higher dew point is acceptable, the Flow Capacity will increase approximately in accordance with the following multipliers:

Dew Point

39°F

45°F

50°F

Flow Capacity Multiplier

1.05

1.15

1.20

Moisture Removal Data

Temp at Receiver Tank

System Tank

Lbs. Condensed Per 100 CFM

Lbs. Per 8 Hr. Shift

Gallons Per 8 Hr. Shift

120

70

.05613

26.94

3.23

100

70

.02455

11.78

1.41

90

70

.01399

6.718

.81

80

70

.005965

.005965

.34

120

50

.06386

.06386

3.67

100

50

.03227

15.49

1.86

90

50

.02172

10.43

1.25

80

50

.01369

6.571

.79

120

35

.06714

32.23

3.86

100

35

.03556

17.07

2.05

90

35

.02501

12.00

1.44

80

35

.01698

8.149

.98

Standard Instrument Panels

 

 

A

B

C

D

E

F

On/Off Switch/Light

 

X

X

X

X